Commissioning a Production Line for Magnetizing Magnetic Steel for New Energy Vehicle Drive Motors: A Six-Step Guide
End-to-End Solution for Magnetization Automation
Automated Magnetic Charging Integrated Solution
The most common pitfalls when commissioning a production line for magnetizing drive motors in new energy vehicles are skipping steps and omitting steps that shouldn’t be omitted. By diligently following these six steps, the failure rate in mass production can be reduced by 70 percent.

Step 1: Position the equipment. Since the pulse magnetizer is a high-voltage discharge device, it should be placed in an area free from moisture, dust, and strong vibrations. Keep the distance between the main unit and the power distribution cabinet within 3 meters to minimize line losses.
Step 2: Electrical Connections. The three-phase power supply must be connected through a dedicated circuit breaker and a ground-fault circuit interrupter (GFCI), with a grounding resistance of ≤4 Ω. Jiuju magnetizing equipment comes standard with a real-time grounding status monitoring module that automatically locks the discharge circuit in the event of poor grounding. Control signal wires and power lines must be routed through separate cable trays to prevent electromagnetic interference from causing false triggers.
Step 3: Safety Check. Verify each item individually, including the emergency stop, safety door interlock, and discharge indicator. When charging the capacitor for the first time, gradually increase the voltage in five stages from the minimum voltage to the rated value, holding each stage for 5 minutes to monitor for any abnormalities.

Step 4: No-load test. Without the magnet installed, trigger magnetization using the production parameters. Use an oscilloscope to capture the discharge waveform and compare it to the factory waveform. If the deviation exceeds 10%, check the wiring or capacitors.
Step 5: Saturation curve tuning. Take a standard magnet sample and apply a stepwise increase in magnetizing voltage from low to high while measuring the magnetic flux. Identify the inflection point voltage at which the magnetic flux stops increasing, and set the production voltage to 1.2 times the inflection point voltage.