JiuJu Magnetic Stripe Magnetization Video Case: Medical Magnetic Stripe Magnetization
End-to-End Solution for Magnetization Automation
Automated Magnetic Charging Integrated Solution
Medical magnetic stripe is widely used in medical credentials such as consultation cards and health insurance cards, which are used to store key data such as patients' basic information and health insurance enrollment information. Due to the frequency of use and the external environment, the magnetic stripe may become magnetically weakened or demagnetized, resulting in the inability of the equipment to read the information, and then need to be magnetized. The core principle of magnetization is to rearranging the magnetic material in the magnetic stripe through a specific strength magnetic field to restore the storage and reading function, which is only applicable to the situation of weakened or slightly demagnetized magnetic stripe, physical damage or chip.
I. Standard process of magnetic stripe magnetization for medical treatment
Medical magnetic stripe magnetization should follow a standardized process to protect the magnetization effect and avoid information damage, different organizations may have differences in equipment models, the specific operation is slightly adjusted:
1. Pre-preparation and verification of information
The staff first verifies the information of the person to whom the medical card belongs, the type of card, and checks whether there is any serious physical damage to the card. If there are breaks, serious scratches, etc., the user should be informed that the magnetization may not be effective and it is recommended that the card be replaced. At the same time, the staff will prepare matching magnetizing equipment and check whether the operating status of the equipment and the magnetic field strength are in line with the industry norms.
2. Commissioning of equipment parameters
According to the type and specification of magnetic stripe debugging equipment parameters, the core including magnetic field strength, magnetization speed, etc., such as health insurance cards need to follow the technical standards of the health insurance system. After debugging with a blank test magnetic stripe test charging, to verify the accuracy of the parameters.
3. Formal magnetization operations
The eligible medical card is smoothly placed into the magnetizing slot according to the guiding direction. After starting the equipment, the magnetic head generates a stable magnetic field and the magnetic particles are reoriented and rearranged to complete the magnetization when the magnetic stripe passes through, and the process takes only a few seconds.
4. Post-magnetization verification and validation
After removing the card, test it through the healthcare system's card reading equipment to verify that the information is displayed properly. If it cannot be read, troubleshoot parameter issues or magnetic stripe damage and process or recommend card replacement, respectively.
Magnetization of Magnetic Materials
3C Electronic Magnetization
Motor Rotor Magnetization
Car Speaker Magnetization
New Energy Vehicle Industry
Medical Equipment Industry
Previous. JiuJu Magnetizing Video Case: Rubber Silicone and NdFeB MagnetizingNEXT STORY. 硅胶磁材产品的充磁案例—久巨充磁机
Jiu Ju Magnetizer













