Before starting the Jiuju 3000V General-Purpose Magnetizing Machine, first inspect the wiring, connections, and external components to ensure they are in good condition, and confirm that the magnetizing fixture is securely positioned with no looseness. After connecting the power supply, wait for the equipment to complete its self-test. Set parameters such as magnetization voltage and duration as needed, and verify that the parameters match the product specifications. Gently place the workpiece to be magnetized into the positioning fixture, ensuring it is properly aligned and secured, then close the safety cabinet door. Confirm that the work area is free of unauthorized personnel and debris, then press the magnetization start button to begin the process. After the process is complete, wait for the equipment to fully depressurize before removing the workpiece to inspect the magnetization results. During batch operations, periodically check the equipment’s operating status. Once all processing is complete, shut down the equipment power supply in sequence, tidy up the workstation, clean the work area, and maintain accurate operation records.